High Current Adapter for NI myRIO
Overview
The High Current Adapter for NI myRIO allows you drive high power low speed currents using relays and open drain N-FET otputs trough MXP connector on your myRIO. The switched signals are connected with screw terminals. For open drains a power supply is needed.
Key Features:
-
Supports 3V…16V power voltage(external power supply required)
-
4 Open drain outputs
-
Continuous current:3.0A(25°C)/2.2A(85°C)
-
Peak output current:4.1A(t<5s)
-
-
4 Standard 3 terminal relay outputs
-
Common, Normally Closed, Normally Open
-
Relay output max switching voltage:30V
-
Rated current:1A
-
-
34-pin female breakout allowing direct access to signal pins
-
Uses the myRIO Expansion Port(MXP) connector
Connector Pin-outs
Relay connectors:
Signal | Description |
---|---|
NOx | Normal Open |
NCx | Normal Close |
COMx | Common terminal |
Open Drains:
Signal | Description |
---|---|
ODx- | Open Drain negative terminal |
ODx+ , PWR+ | Supply voltage (internally connected) |
PWR- | Ground |
Using the Adapter with myRIO
*Relays* are single side stable Normal Connected betweenNCand COM terminals. A logic “high” will energize the coil and the COM will be shorted to NO.
*Open Drains* connectors are meant to be used with two polarized pins/channel. The OD+ is connected to PWR positive power terminal. The OD- is equipped with transient suppression diodes to the PWR. Connect open drains power supply(+PWR-) respecting the polarity. PWR should not exceed 16VDC.
Note:If you need different supplies for different channels, assure suppression diodes to your supply voltages, especially when use inductive loads.